| Roofing Cladding Normal Profile Load Tables Proliner 1000/32 (0.5mm) |
|
The Span Tables below have been created in accordance with EN 1993-1-3 (Eurocode EC3) and calculated by the Steel Construction Institute (SCI). The values are based on a maximum permitted deflection of Span/200 under imposed load. |
| Load factor (working load to ultimate) |
1.5 (in accordance with Eurocode). |
| Deflection for limit of span |
L/200 |
|
| GRAVITY parameters |
0.5mm |
| Bottom flange in compression |
|
| Moment capacity (kNm/m) |
0.824 |
| Inertia (cm4/m) |
7.288 |
| Bottom flange in tension |
|
| Moment capacity (kNm/m) |
0.699 |
| Inertia (cm4/m) |
7.31 |
|
|
| Shear resistance (kN/m) |
19.953 |
| Web crushing mid (kN/m) |
4.903 |
| Web crushing end (kN/m) |
2.452 |
|
|
| Inertia gross section (cm4/m) |
8.596 |
|
| |
Proliner 1000/32 - 0.5mm |
Span/Load Table - GRAVITY - Working load UDL (kN/m2) |
| GRAVITY |
Span in Metres |
Span
Type |
Design
Case |
1.0 |
1.1 |
1.2 |
1.3 |
1.4 |
1.5 |
1.6 |
1.7 |
1.8 |
1.9 |
2.0 |
2.1 |
2.2 |
|
| Single |
Moment |
3.73 |
3.08 |
2.59 |
2.21 |
1.90 |
1.66 |
1.46 |
1.29 |
1.15 |
1.03 |
0.93 |
0.85 |
0.77 |
Inertia |
6.24 |
4.69 |
3.61 |
2.84 |
2.27 |
1.85 |
1.52 |
1.27 |
1.07 |
0.91 |
0.78 |
0.67 |
0.59 |
Reaction |
3.27 |
2.97 |
2.72 |
2.51 |
2.34 |
2.18 |
2.04 |
1.92 |
1.82 |
1.72 |
1.63 |
1.56 |
1.49 |
Limiting |
3.27 |
2.97 |
2.59 |
2.21 |
1.90 |
1.66 |
1.46 |
1.27 |
1.07 |
0.91 |
0.78 |
0.67 |
0.59 |
|
| Double |
Moment |
4.39 |
3.63 |
3.05 |
2.60 |
2.24 |
1.95 |
1.72 |
1.52 |
1.36 |
1.22 |
1.10 |
1.00 |
0.91 |
Inertia |
10.40 |
7.81 |
6.02 |
4.73 |
3.79 |
3.08 |
2.54 |
2.12 |
1.78 |
1.52 |
1.30 |
1.12 |
0.98 |
Reaction |
2.61 |
2.38 |
2.18 |
2.01 |
1.87 |
1.74 |
1.63 |
1.54 |
1.45 |
1.38 |
1.31 |
1.25 |
1.19 |
Interaction |
2.05 |
1.80 |
1.59 |
1.42 |
1.27 |
1.15 |
1.05 |
0.96 |
0.88 |
0.81 |
0.75 |
0.69 |
0.64 |
Limiting |
2.05 |
1.80 |
1.59 |
1.42 |
1.27 |
1.15 |
1.05 |
0.96 |
0.88 |
0.81 |
0.75 |
0.69 |
0.64 |
|
| Multiple |
Moment |
5.49 |
4.54 |
3.81 |
3.25 |
2.80 |
2.44 |
2.15 |
1.90 |
1.70 |
1.52 |
1.37 |
1.25 |
1.13 |
Inertia |
10.40 |
7.81 |
6.02 |
4.73 |
3.79 |
3.08 |
2.54 |
2.12 |
1.78 |
1.52 |
1.30 |
1.12 |
0.98 |
Reaction |
2.97 |
2.70 |
2.48 |
2.29 |
2.12 |
1.98 |
1.86 |
1.75 |
1.65 |
1.56 |
1.49 |
1.42 |
1.35 |
Interaction |
2.41 |
2.12 |
1.88 |
1.68 |
1.51 |
1.37 |
1.24 |
1.14 |
1.05 |
0.96 |
0.89 |
0.83 |
0.77 |
Limiting |
2.41 |
2.12 |
1.88 |
1.68 |
1.51 |
1.37 |
1.24 |
1.14 |
1.05 |
0.96 |
0.89 |
0.83 |
0.77 |
| |
Proliner 1000/32 - 0.5mm |
Span/Load Table - UPLIFT - Working load UDL (kN/m2) |
| UPLIFT |
Span in Metres |
Span
Type |
Design
Case |
1.0 |
1.1 |
1.2 |
1.3 |
1.4 |
1.5 |
1.6 |
1.7 |
1.8 |
1.9 |
2.0 |
2.1 |
2.2 |
|
| Single |
Moment |
4.39 |
3.63 |
3.05 |
2.60 |
2.24 |
1.95 |
1.72 |
1.52 |
1.36 |
1.22 |
1.10 |
1.00 |
0.91 |
Inertia |
6.23 |
4.68 |
3.60 |
2.84 |
2.27 |
1.85 |
1.52 |
1.27 |
1.07 |
0.91 |
0.78 |
0.67 |
0.58 |
Reaction |
3.27 |
2.97 |
2.72 |
2.51 |
2.34 |
2.18 |
2.04 |
1.92 |
1.82 |
1.72 |
1.63 |
1.56 |
1.49 |
Limiting |
3.27 |
2.97 |
2.72 |
2.51 |
2.24 |
1.85 |
1.52 |
1.27 |
1.07 |
0.91 |
0.78 |
0.67 |
0.58 |
|
| Double |
Moment |
3.73 |
3.08 |
2.59 |
2.21 |
1.90 |
1.66 |
1.46 |
1.29 |
1.15 |
1.03 |
0.93 |
0.85 |
0.77 |
Inertia |
10.38 |
7.80 |
6.01 |
4.73 |
3.78 |
3.08 |
2.53 |
2.11 |
1.78 |
1.51 |
1.30 |
1.12 |
0.97 |
Reaction |
2.61 |
2.38 |
2.18 |
2.01 |
1.87 |
1.74 |
1.63 |
1.54 |
1.45 |
1.38 |
1.31 |
1.25 |
1.19 |
Interaction |
1.92 |
1.68 |
1.48 |
1.32 |
1.18 |
1.06 |
0.96 |
0.88 |
0.80 |
0.74 |
0.68 |
0.63 |
0.58 |
Limiting |
1.92 |
1.68 |
1.48 |
1.32 |
1.18 |
1.06 |
0.96 |
0.88 |
0.80 |
0.74 |
0.68 |
0.63 |
0.58 |
|
| Multiple |
Moment |
4.66 |
3.85 |
3.24 |
2.76 |
2.38 |
2.07 |
1.82 |
1.61 |
1.44 |
1.29 |
1.17 |
1.06 |
0.96 |
Inertia |
10.38 |
7.80 |
6.01 |
4.73 |
3.78 |
3.08 |
2.53 |
2.11 |
1.78 |
1.51 |
1.30 |
1.12 |
0.97 |
Reaction |
2.97 |
2.70 |
2.48 |
2.29 |
2.12 |
1.98 |
1.86 |
1.75 |
1.65 |
1.56 |
1.49 |
1.42 |
1.35 |
Interaction |
2.27 |
1.98 |
1.75 |
1.56 |
1.40 |
1.27 |
1.15 |
1.05 |
0.96 |
0.88 |
0.82 |
0.76 |
0.70 |
Limiting |
2.27 |
1.98 |
1.75 |
1.56 |
1.40 |
1.27 |
1.15 |
1.05 |
0.96 |
0.88 |
0.82 |
0.76 |
0.70 |
| |
 |
'SCI Assessed Quality Mark'. This mark testifies that the Steel Construction Institute (SCI) has independently verified the technical data above. |
|
|
| Figures and Comments given here are given for guidance purposes only. While care has been taken to ensure accuracy Duggan Profiles & Steel Service Centre Ltd. and its related companies do not accept liability for errors / or omissions. Customers should satisfy themselves of the suitability of the products supplied or manufactured by Duggan Profiles & Steel Service Centre Ltd. for the use intended. |