ProSigma+ STIFFENED CLEATS
The addition of stiffeners significantly improves the load carrying capacity of all forms of cleats. (Refer to the Load data section on the Introduction page for full details). Where situations demand stiffened versions of all types of both Bolt on and Weld-on cleats are available to suit all section sizes subject to a maximum overall length of 450mm. The addition of stiffening ribs is particularly relevant where cleats are extended due to the rapid reduction in capacity as length increases. Apart from the added stiffening rib these cleats are dimensionally identical to their standard counterparts and fit as indicated by the diagrams in the “General Information” section of the Introduction page. They can be used with purlins, rails and Cee sections and product codes for most available options are listed on this page; refer to the “Unprimed Cleats” section if looking for information on stiffened unprimed bolt-on cleats or stiffened and extended unprimed bolt-on cleats. Dimensioned drawings of typical examples in both bolt-on and weld-on formats are included on this page along with full scale CAD drawings in similar style.

The diagram below shows typical examples of stiffened versions of bolt on and weld on cleats. It must be noted that the maximum available extension for manufacturing purposes is governed by the 450 maximum overall height. Note also the harness hole is located in the stiffener.
Stiffened Cleat
 
Stiffened cleats in Weld-on format are supplied without any primer or other form of corrosion protection while bolt-on versions are supplied primed unless otherwise requested. Stiffened cleats are made to order and extended lead times apply.

Load Data:

Structural data for these cleats is included here. The moment capacities for stiffened cleats listed should be used. The quick reference table does not provide data for stiffened cleats and should not be used. The addition of stiffeners significantly increases cleat capacity so this is an option if unstiffened versions are inadequate. Where the addition of stiffeners is still insufficient to offer the required support another form of support such as hot rolled stubs must be used.

ProSigma+ Stiffened Cleat product codes and drawings:
  Code: Description: DXF File PDF File
Stiffened Cleat DP-CLW145S 145 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW175S 175 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW205S 205 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW235S 235 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW265S 265 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW300S 300 Stiffened Weld-on Cleat: AutoCad File PDF File
DP-CLW325S 325 Stiffened Weld-on Cleat: AutoCad File PDF File
  DP-CLW145SL 145 Stiffened Extended Weld-on Cleat: AutoCad File PDF File
DP-CLW175SL 175 Stiffened Extended Weld-on Cleat:
DP-CLW205SL 205 Stiffened Extended Weld-on Cleat:
DP-CLW235SL 235 Stiffened Extended Weld-on Cleat:
DP-CLW265SL 265 Stiffened Extended Weld-on Cleat:
DP-CLW300SL 300 Stiffened Extended Weld-on Cleat:
DP-CLW325SL 325 Stiffened Extended Weld-on Cleat:
  DP-CLB145S 145 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB175S 175 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB205S 205 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB235S 235 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB265S 265 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB300S 300 Stiffened Bolt-on Cleat: AutoCad File PDF File
DP-CLB325S 325 Stiffened Bolt-on Cleat: AutoCad File PDF File
  DP-CLB145SL 145 Stiffened Extended Bolt-on Cleat: AutoCad File PDF File
DP-CLB175SL 175 Stiffened Extended Bolt-on Cleat:
DP-CLB205SL 205 Stiffened Extended Bolt-on Cleat:
DP-CLB235SL 235 Stiffened Extended Bolt-on Cleat:
DP-CLB265SL 265 Stiffened Extended Bolt-on Cleat:
DP-CLB300SL 300 Stiffened Extended Bolt-on Cleat:
DP-CLB325SL 325 Stiffened Extended Bolt-on Cleat:
Click on the DXF or PDF icons above to download the CAD (.dxf) or .pdf file.

Trouble downloading?
Right-Click on the DXF icon: this will bring up a menu where you can click on either
'Save Target As' or 'Save Link As'.
Then, after saving the DXF file to your computer you can run your CAD software
and open the DXF file that you saved.