| Brochures | Recruitment | Disclaimer |
Duggan Steel Group
Website Address

DUGGAN PROFILES &
STEEL SERVICE CENTRE Ltd.

Proliner
Roofing Cladding Normal Profile Load Table Proliner 1000/20
Profile Proliner 1000/20
20mm Deep Profile - 1000mm Cover Width (Material Spec.: Fe E 280 G) Applied Load in kN/m2
Span in Metres
Section Type: Thick. mm Load Type: 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
 
Single

 

0.4 Dead + Super 1.69 0.96 0.59 0.39 0.26          
  Wind Suction 1.28 0.76 0.49 0.34 0.25          
0.7 Dead + Super 3.58 2.05 1.27 0.83 0.56 0.39 0.28 0.20    
  Wind Suction 2.62 1.55 1.00 0.69 0.50 0.38 0.30 0.25    
 
Double 0.4 Dead + Super 1.78 1.22 0.89 0.67 0.46 0.32 0.24      
  Wind Suction 1.93 1.24 0.79 0.54 0.39 0.30 0.23      
0.7 Dead + Super 3.98 2.75 2.00 1.42 0.98 0.70 0.51 0.38 0.28 0.22
  Wind Suction 4.33 2.53 1.62 1.11 0.79 0.60 0.46 0.37 0.31 0.26
 
Multiple 0.4 Dead + Super 2.23 1.54 1.01 0.67 0.46 0.32 0.24      
  Wind Suction 2.11 1.24 0.79 0.54 0.39 0.30 0.23      
0.7 Dead + Super 5.00 3.45 2.15 1.42 0.98 0.70 0.51 0.38 0.28 0.22
  Wind Suction 4.33 2.53 1.62 1.11 0.79 0.60 0.46 0.37 0.31 0.26
 
Deflection: Dead + Super Loads = L/200
Note: All intermediate values within the limits of the table may be obtained by linear interpolation.

Duggan Profiles & Steel Service Centre Ltd.
Dublin Road,
Kilkenny - Ireland
Tel.: +353-56-7722485 - Fax: +353-56-7763411
E-mail: salesdp@steel.ie

© Copyright Duggan Steel Group Ltd. 2008
webmaster@steel.ie
Last update: 29 August, 2008
Copyright Duggan Steel Group 2008

CIF ISO9000