1000/32 Roof & Reverse Profiles |
|
| Roofing Cladding Normal Profile Load Table |
32mm Deep Profile
1000mm Cover Width
(Material Spec.: Fe E 320 G) |
Applied Load in kN/m2 |
| Span in Metres |
| Section Type: |
Thick. mm |
Load Type: |
1.2 |
1.4 |
1.6 |
1.8 |
2.0 |
2.2 |
2.4 |
2.6 |
2.8 |
3.0 |
|
| Single
|
0.55 |
Dead + Super |
4.49 |
2.84 |
1.88 |
1.31 |
0.94 |
0.70 |
0.52 |
|
|
|
| |
Wind Suction |
4.19 |
2.66 |
1.80 |
1.28 |
0.94 |
0.72 |
0.57 |
|
|
|
| 0.7 |
Dead + Super |
6.21 |
3.89 |
2.58 |
1.80 |
1.29 |
0.96 |
0.72 |
0.55 |
|
|
| |
Wind Suction |
5.81 |
3.68 |
2.49 |
1.77 |
1.31 |
1.00 |
0.78 |
0.63 |
|
|
|
| Double |
0.55 |
Dead + Super |
3.93 |
2.88 |
2.19 |
1.72 |
1.38 |
1.14 |
0.91 |
0.70 |
0.55 |
|
| |
Wind Suction |
5.24 |
3.86 |
2.97 |
2.36 |
1.92 |
1.59 |
1.32 |
1.05 |
0.85 |
|
| 0.7 |
Dead + Super |
5.58 |
4.08 |
3.11 |
2.45 |
1.97 |
1.62 |
1.24 |
0.97 |
0.76 |
0.61 |
| |
Wind Suction |
7.53 |
5.55 |
4.26 |
3.38 |
2.75 |
2.29 |
1.81 |
1.43 |
1.16 |
0.96 |
|
| Multiple |
0.55 |
Dead + Super |
4.93 |
3.61 |
2.75 |
2.16 |
1.60 |
1.19 |
0.91 |
0.70 |
0.55 |
|
| |
Wind Suction |
6.54 |
4.82 |
3.70 |
2.93 |
2.25 |
1.70 |
1.32 |
1.05 |
0.85 |
|
| 0.7 |
Dead + Super |
6.99 |
5.12 |
3.91 |
3.04 |
2.20 |
1.63 |
1.24 |
0.97 |
0.76 |
0.61 |
| |
Wind Suction |
9.40 |
6.92 |
5.31 |
4.20 |
3.08 |
2.33 |
1.81 |
1.43 |
1.16 |
0.96 |
|
Deflection: Dead + Super Loads = L/200 Deflection: Wind Suction Loads = L/150
Note: All intermediate values within the limits of the table may be obtained by linear interpolation. |
| |
Figures and Comments given here are given for guidance purposes only. While care has been taken to ensure accuracy Duggan Profiles & Steel Service Centre Ltd. and its related companies do not accept liability for errors / or omissions. Customers should satisfy themselves of the suitability of the products supplied or manufactured by Duggan Profiles & Steel Service Centre Ltd. for the use intended. |